TM 55-1945-205-24-2
0027 00 2
0027 00
CORRECTIVE ACTION
Replace the capacitor. (WP 0111 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-2)
MALFUNCTION
The fan motor is defective.
CORRECTIVE ACTION
Replace fan motor. (WP 0108 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-2)
MALFUNCTION
The capillary tube and strainer are restricted or plugged.
CORRECTIVE ACTION
Clean or replace the capillary tube and strainer as required. (WP 0106 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-2)
MALFUNCTION
Air is in the system.
CORRECTIVE ACTION
Service air conditioning system. Contact depot maintenance.
MALFUNCTION
Pressure in the system is not equalized.
CORRECTIVE ACTION
Service the air conditioning system. Contact depot maintenance.
END OF WORK PACKAGE