TM 55-1945-205-24-20134 00 10134 00UNIT LEVEL MAINTENANCEROLL-ON/ROLL-OFF DISCHARGE FACILITYLIGHT TOWER BATTERY NEGATIVE LEAD TERMINALREMOVAL AND INSTALLATIONINITIAL SETUP:ToolsTool Kit, General Mechanic’s (Rail and Marine) (Item 82, WP 0359 00)Gloves, Men’s and Women’s (Leather Palm) (Item 27, WP 0359 00)Goggles, Sun, Wind and Dust (Safety) (Item 29, WP 0359 00)Helmet, Safety (Brown) (Item 33, WP 0359 00)Life Preserver, Vest (Item 38, WP 0359 00)Puller, Battery Terminal (Item 52, WP 0359 00)Personnel RequiredEngineer 88LREMOVE LIGHT TOWER BATTERY NEGATIVE LEAD TERMINALWARNINGAll personnel must wear personal flotation device, hard hat, safety shoes, and gloves during RRDF operations and maintenance. Failure to observe these precautions could result in serious injury or death.NOTEThe negative battery post is identified by a raised negative sign stamped on the battery.1.Open starboard light tower door.2.On battery (1), loosen hex nut (2) on negative lead terminal (3).3.Using a battery terminal puller, remove negative lead terminal (3) from negative post (4).15234
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business