TM 55-1945-205-24-2
0134 00 1
0134 00
UNIT LEVEL MAINTENANCE
ROLL-ON/ROLL-OFF DISCHARGE FACILITY
LIGHT TOWER BATTERY NEGATIVE LEAD TERMINAL
REMOVAL AND INSTALLATION
INITIAL SETUP:
Tools
Tool Kit, General Mechanics (Rail and Marine) (Item 82, WP 0359 00)
Gloves, Mens and Womens (Leather Palm) (Item 27, WP 0359 00)
Goggles, Sun, Wind and Dust (Safety) (Item 29, WP 0359 00)
Helmet, Safety (Brown) (Item 33, WP 0359 00)
Life Preserver, Vest (Item 38, WP 0359 00)
Puller, Battery Terminal (Item 52, WP 0359 00)
Personnel Required
Engineer 88L
REMOVE LIGHT TOWER BATTERY NEGATIVE LEAD TERMINAL
WARNING
All personnel must wear personal flotation device, hard hat, safety shoes, and
gloves during RRDF operations and maintenance. Failure to observe these
precautions could result in serious injury or death.
NOTE
The negative battery post is identified by a raised negative sign stamped on the battery.
1.
Open starboard light tower door.
2.
On battery (1), loosen hex nut (2) on negative lead terminal (3).
3.
Using a battery terminal puller, remove negative lead terminal (3) from negative post (4).
1
5
2
3
4