INSTALL LIGHT TOWER PINTLE AND BRACKET
INSTALL LIGHT TOWER RAISE/LOWER WINCH CABLE - TM-55-1945-205-24-2_622
TM-55-1945-205-24-2 Modular Causeway System (MCS) Roll-On/Roll-Off Discharge Facility Model (RRDF) RRDF-1 NSN 1945-01-473-2282 Manual
Page Navigation
503
504
505
506
507
508
509
510
511
512
513
TM 55-1945-205-24-2
0201 00 1
0201 00
DIRECT SUPPORT MAINTENANCE
ROLL-ON/ROLL-OFF DISCHARGE FACILITY
LIGHT TOWER RAISE/LOWER WINCH CABLE
REPLACEMENT
INITIAL SETUP:
Tools
Tool Kit, General Mechanic’s (Item 81, WP 0359 00)
Gloves, Men’s and Women’s (Leather Palm) (Item 27, WP 0359 00)
Goggles, Sun, Wind and Dust (Safety) (Item 29, WP 0359 00)
Helmet, Safety (Brown) (Item 33, WP 0359 00)
Life Preserver, Vest (Item 38, WP 0359 00)
Materials/Parts
Cable
(33968)
PN 43210327
Personnel Required
Engineer 88L
REMOVE LIGHT TOWER RAISE/LOWER WINCH CABLE
WARNING
All personnel must wear personal flotation device, hard hat, safety shoes and gloves
during RRDF operations and maintenance. Failure to observe these precautions
could result in serious injury or death.
1.
Rotate light tower raise/lower winch (1) counterclockwise to unreel cable (2).
2.
Loosen two screws (3) on metal strap (4) and remove cable (2) from winch (1). Discard cable (2).
1
2
3
4