REMOVE LIGHT TOWER - TOWER ASSEMBLY - TM-55-1945-205-24-2_648
LIGHT TOWER - TOWER ASSEMBLY TRUNNION - TM-55-1945-205-24-2_651
TM-55-1945-205-24-2 Modular Causeway System (MCS) Roll-On/Roll-Off Discharge Facility Model (RRDF) RRDF-1 NSN 1945-01-473-2282 Manual
Page Navigation
528
529
530
531
532
533
534
535
536
537
538
TM 55-1945-205-24-2
0211 00 3/4 blank
0211 00
11. Remove light tower - tower extend winch. (WP 0213 00)
12. Remove light tower - tower extend cables. (WP 0217 00)
13. Discard tower assembly (7).
INSTALL LIGHT TOWER - TOWER ASSEMBLY
1.
Install the light tower - tower extend cables. (WP 0217 00)
2.
Install the light tower - tower extend winch. (WP 0213 00)
3.
Install the light tower pivot support. (WP 0209 00)
4.
Install the light tower electrical system
junction box
electrical cable. (WP 0136 00)
5.
Install the light tower - tower electrical cable shroud. (WP 0215 00)
6.
Install the light tower - tower cross bar. (WP 0214 00)
WARNING
7.
Using crane and sling, position new tower assembly (7) over tower support (8).
8.
When the guide holes align on the tower support (8) and tower pivot support (9), install the pivot pin (3).
9.
Install the retaining bolt (2) and nut (1) on pivot pin (3) and tighten nut (1).
WARNING
10. Lower the tower assembly (7) onto tower rest (5) and secure tower assembly (7) with tower rest retaining pin (4).
11. Remove sling from tower assembly (7).
12. Install light tower battery negative lead terminal. (WP 0134 00)
END OF WORK PACKAGE