TM 55-1945-205-24-2
0007 00 1
0007 00
OPERATOR MAINTENANCE
ROLL-ON/ROLL-OFF DISCHARGE FACILITY
LIGHT TOWER
TROUBLESHOOTING PROCEDURES
INITIAL SETUP:
Test Equipment
Multimeter
(Item 43, WP 0359 00)
Tools
Tool Kit, General Mechanic’s (Item 81, WP 0359 00)
Tool Kit, General Mechanic’s (Rail and Marine) (Item 82, WP 0359 00)
Personnel Required
Engineer 88L
References
TM 55-1945-205-10-2
TROUBLESHOOTING PROCEDURE
LIGHTS WILL NOT ILLUMINATE
SYMPTOM
Light(s) on tower assembly do not illuminate.
MALFUNCTION
Lamp bulb(s) is defective.
CORRECTIVE ACTION
Replace lamp bulb. (WP 0156 00)
Perform operational check
of light tower engine. (TM 55-1945-205-10-2)
MALFUNCTION
Light tower junction box electrical cable is damaged or defective.
CORRECTIVE ACTION
Use a
multimeter
to check continuity of wiring of junction box electrical cable. If
continuity is not present, replace light tower
junction box
electrical cable. (WP 0136 00)
Perform operational check
of light tower engine. (TM 55-1945-205-10-2)