TM 55-1945-205-24-2
0007 00 3/4 blank
0007 00
MALFUNCTION
Open circuit between LAMP toggle switch(s) and MAIN BREAKER circuit breaker.
CORRECTIVE ACTION
Using a multimeter, check for 120 VDC at LAMP toggle switch(s).
If 120 VDC is present, use a multimeter to check continuity of wiring between LAMP
toggle switch(s) and MAIN BREAKER circuit breaker. If continuity is not present, repair/
replace wiring as necessary. (WP 0348 00)
If 120 VDC is not present, replace MAIN BREAKER circuit breaker on control panel.
(WP 0151 00)
Perform operational check of light tower engine. (TM 55-1945-205-10-2)
MALFUNCTION
Open circuit between MAIN BREAKER circuit breaker and light tower generator.
CORRECTIVE ACTION
Using a multimeter, check for 120 VDC at MAIN BREAKER circuit breaker.
If 120 VDC is present, use a multimeter to check continuity of wiring between MAIN
BREAKER circuit breaker and generator. If continuity is not present, repair/replace
wiring as necessary. (WP 0348 00)
If 120 VDC is not present, replace light tower generator. Contact Specialized Repair
Activity (SRA).
Perform operational check of light tower engine. (TM 55-1945-205-10-2)
MALFUNCTION
Light tower light(s) still will not illuminate.
CORRECTIVE ACTION
Contact Specialized Repair Activity (SRA).
END OF WORK PACKAGE