TM 55-1945-205-24-2
0303 00 2
0303 00
WARNING
3.
Tag and disconnect rectifier/regulator solid red lead (2) from the terminal strip (3).
4.
Tag and disconnect wiring harness red lead (4) from terminal strip (3).
5.
Connect the ammeter (5) in series between rectifier solid red lead (2) and wiring harness red lead (4).
WARNING
Do not allow the rectifier/regulator red lead, the ammeter or the wiring harness red
lead to touch engine ground with the engine running. Failure to comply could result
in damage to equipment or injury to personnel.
6.
Install RHIB battery negative lead terminal. (WP 0336 00)
7.
Start RHIB engine. (TM 55-1945-205-10-2)
8.
Observe ammeter. Alternator output should reach 12 amps at approximately 4000 RPM.
a.
If alternator output is 12 amps, go to Step 9.
b.
If there is no alternator output or output is below 12 amps, run resistance tests on the stator and the rectifier.
(WP 0304 00)
9.
Shut down RHIB engine. (TM 55-1945-205-10-2)
10. Disconnect ammeter (5).
11. Connect rectifier/regulator solid red lead (2) to terminal strip (3) and remove tag.
12. Connect wiring harness red lead (4) to terminal strip (3) and remove tag.
13. Install terminal strip cover (1).
14. Install RHIB engine cover. (WP 0297 00)
15. Install RHIB battery negative lead terminal. (WP 0336 00)
16. Remove engine from test tank.
END OF WORK PACKAGE