TM 55-1945-205-24-4
0030 00 2
0030 00
MALFUNCTION
The system capacitor is defective.
CORRECTIVE ACTION
Replace the capacitor. (WP 0108 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-4)
MALFUNCTION
The compressor motor is defective.
CORRECTIVE ACTION
Replace compressor motor. Contact depot maintenance.
MALFUNCTION
The fan blade or blower wheel is defective or stuck.
CORRECTIVE ACTION
Free the fan blade or blower wheel and replace as required. (WP 0105 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-4)
MALFUNCTION
Fan blade motor is defective.
CORRECTIVE ACTION
Replace the fan blade motor. (WP 0105 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-4)
MALFUNCTION
The capillary tube and strainer are restricted or plugged.
CORRECTIVE ACTION
Clean and replace the capillary tube and strainer as required. (WP 0103 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-4)