TM 55-1945-205-24-4
0028 00 2
0028 00
CORRECTIVE ACTION
Using multimeter, check continuity of wiring. If continuity is not present, repair/replace
wiring as necessary. (WP 0248 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-4)
MALFUNCTION
Compressor is grounding (shorting) out.
CORRECTIVE ACTION
Repair ground (short) in the compressor or replace compressor as required. Contact
depot maintenance.
MALFUNCTION
The system overload protector is defective.
CORRECTIVE ACTION
Test overload protector. (WP 0107 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-4)
MALFUNCTION
The system capacitor is defective.
CORRECTIVE ACTION
Replace the capacitor. (WP 0108 00)
Perform operational check on heating and air conditioning system.
(TM 55-1945-205-10-4)
MALFUNCTION
The compressor motor is defective.
CORRECTIVE ACTION
Replace compressor motor. Contact depot maintenance.
MALFUNCTION
Pressure is not equalized in the system.
CORRECTIVE ACTION
Service air conditioning system. Contact depot maintenance.
END OF WORK PACKAGE