TM 55-1945-205-24-40029 00 20029 00MALFUNCTIONThermostat contacts are open.CORRECTIVE ACTIONAdjust thermostat to close contacts or replace thermostat as required. (WP 0104 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONSelector switch is defective. CORRECTIVE ACTIONReplace selector switch. Contact depot maintenance.MALFUNCTIONCompressor system wiring is defective.CORRECTIVE ACTIONUsing multimeter, check continuity of wiring to compressor. Replace wiring as necessary. (WP 0248 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONSystem overload protector is open or defective.CORRECTIVE ACTIONTest the overload protector. (WP 0107 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)MALFUNCTIONThe fan motor is defective.CORRECTIVE ACTIONReplace fan motor. (WP 0105 00)Perform operational check on heating and air conditioning system. (TM 55-1945-205-10-4)END OF WORK PACKAGE