TM 55-1945-205-24-4
0110 00 2
0110 00
4.
Loosen stainless steel band (6) between the straight 3 in. PVC pipe (5) and the flex straight coupling (7) and slide
band (6) onto pipe (5).
5.
Remove and retain straight 3 in. PVC pipe (5) with two bands (4, 6) for installation.
6.
Loosen stainless steel band (8) between the flex straight coupling (7) and the straight exhaust PVC pipe (9) and
slide onto pipe (9).
7.
Remove flex straight coupling (7) and discard.
INSTALL PERSONNEL SHELTER INCINERATOR TOILET EXHAUST
FLEXIBLE COUPLINGS
1.
Position stainless steel band (8) between the new flex straight coupling (7) and the straight exhaust PVC pipe (9)
and tighten band (8).
2.
Position stainless steel band (6) between the straight 3 in. PVC pipe (5) and the flex straight coupling (7) and
tighten band (6).
3.
Position stainless steel band (4) between the new flex reducing coupling (2) and the straight 3 in. PVC pipe (5)
and tighten band (4).
4.
Position stainless steel band (1) between the flex reducing coupling (2) and the incinerator toilet 90° elbow (3)
and tighten band (1).
END OF WORK PACKAGE