TM 55-1945-205-24-4
0113 00 1
0113 00
UNIT LEVEL MAINTENANCE
FLOATING CAUSEWAY
PERSONNEL SHELTER VENT FAN
CLEANING AND INSPECTION
INITIAL SETUP:
Tools
Gloves, Chemical (Item 14, WP 0253 00)
Goggles, Industrial (Chipping, Chemical) (Item 17, WP 0253 00)
Apron, Utility (Item 1, WP 0253 00)
Brush, Stencil (Soft Bristle) (Item 4, WP 0253 00)
Materials/Parts
Cleaner (Item 7, WP 0252 00)
Rag, Wiping (Item 35, WP 0252 00)
Personnel Required
Seaman 88K
CLEAN PERSONNEL SHELTER VENT FAN
1.
Position circuit breaker D (1) on the personnel shelter electrical distribution board to the off position.
2.
Pull down personnel shelter vent fan cover (2) located in incinerator toilet compartment overhead to open.
WARNING
3.
Using soft bristle brush and cleaner, clean fan blades (3) and vent cavity (4).
1
CKT D
TOILET LTG & VENT
120VAC, 1PH, 60HZ
FDR (SHLTR PNL)-1L-D(1)
2
3
4
5