TM 55-1945-205-24-4
0114 00 2
0114 00
3.
Remove hex head machine screw (3) from vent fan panel (4).
4.
Remove vent fan panel (4) from vent fan enclosure (5).
5.
Disconnect vent fan wiring harness (6) from plug (7).
6.
Remove three round head screws (8) from vent fan panel (4).
7.
Remove vent fan (9) and discard.
INSTALL PERSONNEL SHELTER VENT FAN
1.
Position new vent fan (9) on vent fan panel (4).
2.
Install three round head screws (8) and tighten.
3.
Connect vent fan wiring harness (6) to plug (7).
4.
Position vent fan panel (4) on vent fan enclosure (5).
5.
Install hex head machine screw (3) in vent fan panel (4) and tighten.
6.
Position and push upward to install and close personnel shelter vent fan cover (2).
7.
Position circuit breaker D (1) on the personnel shelter electrical distribution board to ON.
8.
Perform operational check of personnel shelter vent fan. (TM 55-1945-205-10-4)
END OF WORK PACKAGE