TM 55-1945-205-24-4
0121 00 1
0121 00
DIRECT SUPPORT MAINTENANCE
FLOATING CAUSEWAY
PERSONNEL SHELTER HOSPITAL GRADE STRAIGHT BLADE
ELECTRICAL RECEPTACLE
REPLACEMENT
INITIAL SETUP:
Tools
Tool Kit, General Mechanic’s (Item 53, WP 0253 00)
Materials/Parts
Receptacle, Duplex
(74545)
PN 8200
Personnel Required
Engineer 88L
Equipment Condition
Generator
Shut Down. (TM 9-6115-642-10, TM 9-6115-643-10)
REMOVE PERSONNEL SHELTER HOSPITAL GRADE STRAIGHT BLADE
ELECTRICAL RECEPTACLE
1.
Lift weather cover (1).
2.
Remove screw (2) securing receptacle cover (3) to receptacle (4).
3.
Remove two screws (5) securing receptacle (4) to circuit box (6).
6
7
4
5
1
2
3
5