TM 55-1945-205-24-4
0135 00 1
0135 00
UNIT LEVEL MAINTENANCE
FLOATING CAUSEWAY
LIGHT TOWER ENGINE ALTERNATOR
REPLACEMENT
INITIAL SETUP:
Tools
Tool Kit, General Mechanics (Rail and Marine) (Item 54, WP 0253 00)
Gloves, Mens and Womens (Leather Palm) (Item 16, WP 0253 00)
Goggles, Sun, Wind and Dust (Safety) (Item 18, WP 0253 00)
Helmet, Safety (Brown) (Item 20, WP 0253 00)
Life Preserver, Vest (Item 25, WP 0253 00)
Materials/Parts
Alternator
(33968)
PN 36888170
Personnel Required
Engineer 88L
References
TM 55-1945-205-10-4
Equipment Condition
Light Tower Battery Negative Lead Terminal Removed. (WP 0131 00)
Light Tower Engine Fan Belt Removed. (WP 0180 00)
REMOVE LIGHT TOWER ENGINE ALTERNATOR
WARNING
All personnel must wear personal flotation device, hard hat, safety shoes, and
gloves during FC operations and maintenance. Failure to observe these precautions
could result in serious injury or death.
1.
Tag and disconnect wiring (1) from the alternator (2).