TM 55-1945-205-24-40137 00 10137 00DIRECT SUPPORT MAINTENANCEFLOATING CAUSEWAYLIGHT TOWER ENGINE GLOW PLUGSTESTINGINITIAL SETUP:Test EquipmentMultimeter (Item 30, WP 0253 00)ToolsGloves, Men’s and Women’s (Leather Palm) (Item 16, WP 0253 00)Goggles, Sun, Wind and Dust (Safety) (Item 18, WP 0253 00)Helmet, Safety (Brown) (Item 20, WP 0253 00)Life Preserver, Vest (Item 25, WP 0253 00)Personnel RequiredEngineer 88LEquipment ConditionLight Tower Engine Glow Plugs Removed. (WP 0136 00)TEST LIGHT TOWER ENGINE GLOW PLUGSWARNINGAll personnel must wear personal flotation device, hard hat, safety shoes, and gloves during FC operations and maintenance. Failure to observe these precautions could result in serious injury or death.NOTEThe following steps apply to glow plugs with serial numbers 488290 and below.1.Set multimeter to measure resistance (W).2.Attach multimeter negative lead to glow plug threaded case (1).3.Attach multimeter positive lead to glow plug terminal (2).4.Verify a resistance of 1.0 - 1.2 W.21