TM 55-1945-205-24-4
0137 00 1
0137 00
DIRECT SUPPORT MAINTENANCE
FLOATING CAUSEWAY
LIGHT TOWER ENGINE GLOW PLUGS
TESTING
INITIAL SETUP:
Test Equipment
Multimeter (Item 30, WP 0253 00)
Tools
Gloves, Mens and Womens (Leather Palm) (Item 16, WP 0253 00)
Goggles, Sun, Wind and Dust (Safety) (Item 18, WP 0253 00)
Helmet, Safety (Brown) (Item 20, WP 0253 00)
Life Preserver, Vest (Item 25, WP 0253 00)
Personnel Required
Engineer 88L
Equipment Condition
Light Tower Engine Glow Plugs Removed. (WP 0136 00)
TEST LIGHT TOWER ENGINE GLOW PLUGS
WARNING
All personnel must wear personal flotation device, hard hat, safety shoes, and
gloves during FC operations and maintenance. Failure to observe these precautions
could result in serious injury or death.
NOTE
The following steps apply to glow plugs with serial numbers 488290 and below.
1.
Set multimeter to measure resistance (W).
2.
Attach multimeter negative lead to glow plug threaded case (1).
3.
Attach multimeter positive lead to glow plug terminal (2).
4.
Verify a resistance of 1.0 - 1.2 W.
2
1