TM 55-1945-205-24-4
0155 00 1
0155 00
DIRECT SUPPORT MAINTENANCE
FLOATING CAUSEWAY
LIGHT TOWER OPTICAL/SOCKET ASSEMBLY
REPAIR
INITIAL SETUP:
Tools
Tool Kit, General Mechanics (Item 53, WP 0253 00)
Gloves, Mens and Womens (Leather Palm) (Item 16, WP 0253 00)
Goggles, Sun, Wind and Dust (Safety) (Item 18, WP 0253 00)
Helmet, Safety (Brown) (Item 20, WP 0253 00)
Life Preserver, Vest (Item 25, WP 0253 00)
Gloves, Chemical (Item 14, WP 0253 00)
Goggles, Industrial (Chipping, Chemical) (Item 17, WP 0253 00)
Apron, Utility (Item 1, WP 0253 00)
Materials/Parts
Gasket, Lens
(33968)
PN 36885309
Gasket, Housing
(33968)
PN 36885325
Cleaner (Item 7, WP 0252 00)
Rag, Wiping (Item 35, WP 0252 00)
Cloth, Cleaning (Item 12, WP 0252 00)
Personnel Required
Interior Electrician 51R
Equipment Condition
Light Tower Battery Negative Lead Terminal Removed. (WP 0131 00)
Light Tower Optical/Socket Assembly Removed. (WP 0154 00)
DISASSEMBLE LIGHT TOWER OPTICAL/SOCKET ASSEMBLY
WARNING
All personnel must wear personal flotation device, hard hat, safety shoes and gloves
during FC operations and maintenance. Failure to observe these precautions could
result in serious injury or death.
NOTE
Repair is limited to replacement of defective items.
1.
Remove nut (1) and bolt (2) from retaining ring (3).