TM 55-1945-205-24-4
0155 00 4
0155 00
6.
Using clean cloth, dry lens.
WARNING
7.
Dispose of contaminated wiping rags in accordance with local procedures.
INSPECT LIGHT TOWER OPTICAL/SOCKET ASSEMBLY
1.
Inspect screws for damaged threads. Replace damaged item(s).
2.
Inspect retaining ring for twisting or bending. Replace damaged item.
3.
Inspect lens for cracks. Replace damaged item.
4.
Inspect socket for damaged threads. Replace damaged item.
5.
Inspect cord for breaks. Replace damaged item.
6.
Inspect cord for frayed insulation. Replace damaged item.
ASSEMBLE LIGHT TOWER OPTICAL/SOCKET ASSEMBLY
1.
Install cord (17) in housing (13).
2.
Connect cord (17) wires, remove tags and tighten screws at base of socket (10).
3.
Position socket (10) on housing (13).
4.
Install two screws (15) in housing (13).
5.
Slide strain relief (16) down cord (17) and tighten.
6.
Position reflector (4) and new gasket (14) on housing (13).
7.
Position reinforcement ring (12) on reflector (4).
8.
Install four screws (11) in reinforcement ring (12). Tighten four screws (11).
9.
Position lamp (9) in socket (10).
10. Rotate lamp (9) clockwise in socket (10). Tighten lamp (9).
11. Position lens bracket (8) on lamp (9).
12. Install lens support (7) in reflector (4).
13. Install new gasket (6) on reflector (4).
14. Install lens (5) in reflector (4).