TM 55-1945-205-24-40198 00 10198 00DIRECT SUPPORT MAINTENANCEFLOATING CAUSEWAYLIGHT TOWER RAISE/LOWER WINCH CABLEREPLACEMENTINITIAL SETUP:ToolsTool Kit, General Mechanic’s (Item 53, WP 0253 00)Gloves, Men’s and Women’s (Leather Palm) (Item 16, WP 0253 00)Goggles, Sun, Wind and Dust (Safety) (Item 18, WP 0253 00)Helmet, Safety (Brown) (Item 20, WP 0253 00)Life Preserver, Vest (Item 25, WP 0253 00)Materials/PartsCable(33968)PN 43210327Personnel RequiredEngineer 88LREMOVE LIGHT TOWER RAISE/LOWER WINCH CABLEWARNINGAll personnel must wear personal flotation device, hard hat, safety shoes and gloves during FC operations and maintenance. Failure to observe these precautions could result in serious injury or death.1.Rotate light tower raise/lower winch (1) counterclockwise to unreel cable (2).2.Loosen two screws (3) on metal strap (4) and remove cable (2) from winch (1). Discard cable (2).1234
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business