TM 55-1945-205-24-4
0198 00 1
0198 00
DIRECT SUPPORT MAINTENANCE
FLOATING CAUSEWAY
LIGHT TOWER RAISE/LOWER WINCH CABLE
REPLACEMENT
INITIAL SETUP:
Tools
Tool Kit, General Mechanics (Item 53, WP 0253 00)
Gloves, Mens and Womens (Leather Palm) (Item 16, WP 0253 00)
Goggles, Sun, Wind and Dust (Safety) (Item 18, WP 0253 00)
Helmet, Safety (Brown) (Item 20, WP 0253 00)
Life Preserver, Vest (Item 25, WP 0253 00)
Materials/Parts
Cable
(33968)
PN 43210327
Personnel Required
Engineer 88L
REMOVE LIGHT TOWER RAISE/LOWER WINCH CABLE
WARNING
All personnel must wear personal flotation device, hard hat, safety shoes and gloves
during FC operations and maintenance. Failure to observe these precautions could
result in serious injury or death.
1.
Rotate light tower raise/lower winch (1) counterclockwise to unreel cable (2).
2.
Loosen two screws (3) on metal strap (4) and remove cable (2) from winch (1). Discard cable (2).
1
2
3
4