TM 55-1945-205-24-40200 00 10200 00UNIT LEVEL MAINTENANCEFLOATING CAUSEWAYLIGHT TOWER DRAWBAR JACKREPLACEMENTINITIAL SETUP:ToolsTool Kit, General Mechanic’s (Rail and Marine) (Item 54, WP 0253 00)Gloves, Men’s and Women’s (Leather Palm) (Item 16, WP 0253 00)Goggles, Sun, Wind and Dust (Safety) (Item 18, WP 0253 00)Helmet, Safety (Brown) (Item 20, WP 0253 00)Life Preserver, Vest (Item 25, WP 0253 00)Pliers, Retaining Ring (Item 34, WP 0253 00)Materials/PartsRing, Snap(33968)PN 36780039Jack, Drawbar(33968)PN 36848455Personnel RequiredEngineer 88LREMOVE LIGHT TOWER DRAWBAR JACKWARNINGAll personnel must wear personal flotation device, hard hat, safety shoes and gloves during FC operations and maintenance. Failure to observe these precautions could result in serious injury or death.1.Using retaining ring pliers, remove ring (1) releasing drawbar jack (2) from drawbar (3).