TM 55-1945-205-24-4
0211 00 1
0211 00
DIRECT SUPPORT MAINTENANCE
FLOATING CAUSEWAY
LIGHT TOWER - TOWER CROSS BAR
REPLACEMENT
INITIAL SETUP:
Tools
Tool Kit, General Mechanic’s (Item 53, WP 0253 00)
Gloves, Men’s and Women’s (Leather Palm) (Item 16, WP 0253 00)
Goggles, Sun, Wind and Dust (Safety) (Item 18, WP 0253 00)
Helmet, Safety (Brown) (Item 20, WP 0253 00)
Life Preserver, Vest (Item 25, WP 0253 00)
Materials/Parts
Bar, Cross
(33968)
PN 43210319
Personnel Required
Engineer 88L
Equipment Condition
Light Tower Battery Negative Lead Terminal Removed. (WP 0131 00)
Telescopic Light Tower Assembly Lowered. (TM 55-1945-205-10-4)
Light Tower Electrical Cable Shroud Removed. (WP 0212 00)
Light Tower Electrical System
Junction Box
Electrical Cable Removed. (WP 0133 00)
Light Tower Electrical System
Junction Box
Removed. (WP 0134 00)
REMOVE LIGHT TOWER - TOWER CROSS BAR
WARNING
All personnel must wear personal flotation device, hard hat, safety shoes and gloves
during FC operations and maintenance. Failure to observe these precautions could
result in serious injury or death.
1.
Remove two nuts (1), four washers (2) and two bolts (3) securing cross bar (4) to tower mounting bracket (5).