TM 55-1945-205-24-4
0210 00 1
0210 00
DIRECT SUPPORT MAINTENANCE
FLOATING CAUSEWAY
LIGHT TOWER - TOWER EXTEND WINCH
REPLACEMENT
INITIAL SETUP:
Tools
Tool Kit, General Mechanics (Item 53, WP 0253 00)
Gloves, Mens and Womens (Leather Palm) (Item 16, WP 0253 00)
Goggles, Sun, Wind and Dust (Safety) (Item 18, WP 0253 00)
Helmet, Safety (Brown) (Item 20, WP 0253 00)
Life Preserver, Vest (Item 25, WP 0253 00)
Materials/Parts
Winch, Tower 1500 lb
(33968)
PN 36869261
Personnel Required
Engineer 88L
Equipment Condition
Light Tower - Tower Extend Cable Removed. (WP 0214 00)
REMOVE LIGHT TOWER - TOWER EXTEND WINCH
WARNING
All personnel must wear personal flotation device, hard hat, safety shoes and gloves
during FC operations and maintenance. Failure to observe these precautions could
result in serious injury or death.
1.
Remove three nuts (1) and bolts (2).