TM 55-1945-205-24-4
0007 00 1
0007 00
OPERATOR MAINTENANCE
FLOATING CAUSEWAY
LIGHT TOWER
TROUBLESHOOTING PROCEDURES
INITIAL SETUP:
Test Equipment
Multimeter (Item 30, WP 0253 00)
Tools
Tool Kit, General Mechanics (Item 53, WP 0253 00)
Tool Kit, General Mechanics (Rail and Marine) (Item 54, WP 0253 00)
Personnel Required
Engineer 88L
References
TM 55-1945-205-10-4
TROUBLESHOOTING PROCEDURE
LIGHTS WILL NOT ILLUMINATE
SYMPTOM
Light(s) on tower assembly do not illuminate.
MALFUNCTION
Lamp bulb(s) is defective.
CORRECTIVE ACTION
Replace lamp bulb. (WP 0153 00)
Perform operational check of light tower engine. (TM 55-1945-205-10-4)
MALFUNCTION
Light tower junction box electrical cable is damaged or defective.
CORRECTIVE ACTION
Use a multimeter to check continuity of wiring of junction box electrical cable. If
continuity is not present, replace light tower junction box electrical cable. (WP 0133 00)
Perform operational check of light tower engine. (TM 55-1945-205-10-4)