TM 55-1945-205-24-40007 00 3/4 blank 0007 00MALFUNCTIONOpen circuit between LAMP toggle switch(s) and MAIN BREAKER circuit breaker.CORRECTIVE ACTIONUsing a multimeter, check for 120 VDC at LAMP toggle switch(s).If 120 VDC is present, use a multimeter to check continuity of wiring between LAMP toggle switch(s) and MAIN BREAKER circuit breaker. If continuity is not present, repair/replace wiring as necessary. (WP 0246 00)If 120 VDC is not present, replace MAIN BREAKER circuit breaker on control panel. (WP 0148 00)Perform operational check of light tower engine. (TM 55-1945-205-10-4)MALFUNCTIONOpen circuit between MAIN BREAKER circuit breaker and light tower generator.CORRECTIVE ACTIONUsing a multimeter, check for 120 VDC at MAIN BREAKER circuit breaker.If 120 VDC is present, use a multimeter to check continuity of wiring between MAIN BREAKER circuit breaker and generator. If continuity is not present, repair/replace wiring as necessary. (WP 0246 00)If 120 VDC is not present, replace light tower generator. Contact Specialized Repair Activity (SRA).Perform operational check of light tower engine. (TM 55-1945-205-10-4)MALFUNCTIONLight tower light(s) still will not illuminate.CORRECTIVE ACTIONContact Specialized Repair Activity (SRA).END OF WORK PACKAGE