TM 55-1945-205-24-4
0009 00 1
0009 00
UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE
FLOATING CAUSEWAY
LIGHT TOWER
TROUBLESHOOTING PROCEDURES
INITIAL SETUP:
Personnel Required
Engineer 88L
References
TM 55-1945-205-10-4
TROUBLESHOOTING PROCEDURE
ENGINE SHUTS DOWN.
SYMPTOM
Engine stops running
MALFUNCTION
Engine fuel filter(s) are contaminated with water or debris.
CORRECTIVE ACTION
Drain fuel filter bowl. (WP 0164 00)
Replace fuel filter element. (WP 0165 00)
Replace in line fuel filter. (WP 0168 00)
Perform operational check of light tower engine. (TM 55-1945-205-10-4)
MALFUNCTION
Air in the fuel system.
CORRECTIVE ACTION
Check for loose couplings, cap nuts, screws and fittings and repair as necessary.
Perform operational check of light tower engine. (TM 55-1945-205-10-4)
MALFUNCTION
Loose wire connections.
CORRECTIVE ACTION
Check for any loose wire connections and tighten as required.
Perform operational check of light tower engine. (TM 55-1945-205-10-4)