TM 55-1945-205-24-4
0012 00 1
0012 00
UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE
FLOATING CAUSEWAY
LIGHT TOWER
TROUBLESHOOTING PROCEDURES
INITIAL SETUP:
Personnel Required
Engineer 88L
References
TM 55-1945-205-10-4
TROUBLESHOOTING PROCEDURE
ENGINE WILL NOT START/RUN
SYMPTOM
Light tower engine will not start/run.
MALFUNCTION
Engine fuel filter(s) are clogged.
CORRECTIVE ACTION
Drain engine fuel filter bowl. (WP 0164 00)
Replace fuel filter element. (WP 0165 00)
Replace in line fuel filter. (WP 0168 00)
Perform operational check of light tower engine. (TM 55-1945-205-10-4)
MALFUNCTION
Loose wire connections.
CORRECTIVE ACTION
Check all wire connections and tighten as required.
Perform operational check of light tower engine. (TM 55-1945-205-10-4)
MALFUNCTION
Battery connections are corroded.
CORRECTIVE ACTION
Clean battery terminals and connectors. (WP 0138 00)
Perform operational check of light tower engine. (TM 55-1945-205-10-4)