AIR CLEANER MOTOR SOLENOID RELAY REPLACEMENT
FUEL SHUTOFF AND PERSONNEL HEATER CIRCUIT BREAKERS REPLACEMENT

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -3 Page Navigation
  161    162    163    164    165  166  167    168    169    170    171  
img
TM 5-5420-226-20-3
AIR CLEANER MOTOR SOLENOID RELAY REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
Position air cleaner motor solenoid relay (A) on mounting plate (B).
1.
2.
Using socket, install two screws (C) and lockwashers (D) securing air cleaner motor solenoid
relay (A) to mouting plate (B).
Using spanner wrench, install electrical connector (E) to air cleaner motor solenoid relay
3.
(A).
Install access plate at commander's
4.
station (page 17-9).
TA168815
End of Task