TM 5-1940-322-24
0060 00
WIRING HARNESS CONNECTOR REPAIR (Contd)
TERMINAL-TYPE CABLE CONNECTOR REPAIR
1.
Strip cable insulation (1) from cable (2) to equal depth of terminal well (4).
2.
Slide insulator (3) over cable insulation (1).
3.
Insert cable (2) into terminal well (4) and crimp.
4.
Slide insulator (3) over crimped end of terminal (5).
5.
6.
Close battery hatch (TM 5-1940-322-10).
3
4
5
1
2
MALE CABLE CONNECTOR REPAIR
1.
Strip cable insulation (6) from cable (7) to equal depth of terminal well (10).
2.
Slide shell (8) and slotted washer (9) over cable insulation (6).
3.
Insert cable (7) into terminal well (10) and crimp.
4.
Place slotted washer (9) over crimped junction at terminal (11).
5.
Slide shell (8) over slotted washer (9) and terminal (11).
6.
7.
Close battery hatch (TM 5-1940-322-10).
8
9
10
11
6
7
FEMALE CABLE CONNECTOR REPAIR
1.
Strip cable insulation (12) from cable (13) to equal depth of terminal well (16).
2.
Slide shell (14) and sleeve (15) over cable insulation (12).
3.
Insert cable (13) into terminal well (16) and crimp.
4.
Slide sleeve (15) and shell (14) over terminal (17).
5.
6.
Close battery hatch (TM 5-1940-322-10).
14
16 17
15
12 13
0060 00-2