TM 5-1940-322-24
0070 00
RAW WATER STRAINER MAINTENANCE (Contd)
NOTE
Both raw water strainers are replaced the same way. This
procedure covers the replacement of one raw water strainer.
REMOVAL
1.
Remove clamps (5) and hoses (6) and (8) from raw water strainer (7).
2.
Remove three locknuts (4), washers (2), screws (1), and raw water strainer (7) from bracket (3).
Discard locknuts (4).
3.
Remove cover (11), basket (10), and O-ring (9) from raw water strainer (7).
CLEANING AND INSPECTION
1.
For general cleaning and inspection instructions, refer to WP 0013 00.
WARNING
Compressed air source must not exceed 30 psi (207 kPa). Wear
eyeshields when cleaning with compressed air. Failure to comply
may result in injury to personnel.
2.
Clean basket (10) with compressed air.
3.
Inspect basket (10) and O-ring (9) for damage. Replace basket (10) or O-ring (9) if damaged.
INSTALLATION
1.
Install O-ring (9) and basket (10) in raw water strainer (7).
2.
Install raw water strainer (7) on bracket (3) with three screws (1), washers (2), and new locknuts (4).
3.
Install hoses (6) and (8) on raw water strainer (7) with clamps (5).
CAUTION
Use care when installing cover on raw water strainer. Failure to
comply may result in damage to raw water strainer and/or O-ring.
4.
Install cover (11) on raw water strainer (7).
5.
If boat is in water, start engine, engage transmission, and check for leaks (TM 5-1940-322-10).
6.
Close hydrojet hatches (TM 5-1940-322-10).
0070 00-2