TM 5-1940-322-24
0131 00
SCOOP CONTROL HYDRAULIC RESERVOIR AND HOSES MAINTENANCE (Contd)
CAUTION
Cap and plug all hoses, connections, and openings immediately
after disconnection to prevent contamination. Remove caps or plugs
prior to installation. Failure to comply may result in damage to
equipment.
NOTE
Both scoop control hydraulic reservoirs and hoses are replaced the
same way. This procedure covers the replacement of one scoop
control hydraulic reservoir and two hoses.
REMOVAL
NOTE
Have container ready to catch oil.
1.
Remove two hose clamps (6) and hoses (10) and (13) from scoop control hydraulic reservoir (1).
2.
Remove two locknuts (2), washers (3), and scoop control hydraulic reservoir (1) from inspection
cover (4). Discard locknuts (2).
3.
Remove hose clamp (12) and hose (13) from hydraulic pump inlet tube (11).
4.
Remove tube elbow (8) from oil cooler adapter (7).
5.
Remove hose clamp (9) and hose (10) from tube elbow (8).
6.
Remove filler cap (15), three screws (14), and filler cap screen (16) from scoop control hydraulic
reservoir cover (17).
7.
Remove four screws (21), lockwashers (20), scoop control hydraulic reservoir cover (17), and
gasket (18) from scoop control hydraulic reservoir housing (1). Discard lockwashers (20) and
gasket (18).
8.
Remove site glass (19) from side of scoop control hydraulic reservoir housing (1).
CLEANING AND INSPECTION
1.
For general cleaning and inspection instructions, refer to WP 0013 00.
CAUTION
Skysol 100 solvent is combustible; DO NOT use or store near heat,
sparks, flame, or other ignition sources. Use mechanical ventilation
whenever product is used in a confined space, heated above
ambient temperatures, or agitated. Keep container sealed when not
in use.
Contact with Skysol 100 may cause skin irritation. Use chemical-
resistant gloves. In case of skin contact, remove any contaminated
clothing and wash skin thoroughly with soap and water. Wash
contaminated clothing before reuse. Eye contact may cause
irritation, tearing, or blurring of vision. Use face shield or goggles
when eye contact may occur. In case of eye contact, flush eyes with
large amounts of water for at least 15 minutes or until irritation
subsides. Inhalation may cause irritation to upper respiratory
passages. DO NOT have food or drink in the vicinity. Failure to
comply may result in injury to personnel.
2.
Clean inside of scoop control hydraulic reservoir housing (1) with Skysol 100 and dry with cloth.
3.
Clean filter screen (16) with Skysol 100 and let air dry.
0131 00-2