TM 5-5420-202-20-2
14.
seated. Check all clearances around
powerplant.
Remove four sling chain hooks from
15.
four lifting eyes of powerplant.
16.
(B), lockwasher (C), and bolt (D) (both
sides).
17.
Using 1-1/2 inch socket and torque wrench,
tighten bolt (D) securing transmission
mounting bracket to 370-375 lb-ft (501-
508 NZm).
18.
Have second technician hold universal joint
with final drive guide adapter.
Using pinch bar, pry final drive adapter
19.
away from final drive into universal
joint (each side).
Fit quick-disconnect ring (E) around
20.
final drive adapter.
Go on to Sheet 16
Change 3