POWERPLANT TESTS (GROUND HOP) - Continued
POWERPLANT TESTS (GROUND HOP) - Continued

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -2 Page Navigation
  28    29    30    31    32  33  34    35    36    37    38  
img
. .
TM 5-5420-202-20-2
POWERPLANT TESTS (GROUND HOP) (Sheet 6 of 16)
Idle Test (Sheet 1 of 1 )
Take all necessary safety precautions to
eliminate possible injury to personnel or
damage to equipment. Stand clear of trans-
mission output flanges whenever the engine
is running.
1.
Start and operate engine until normal operating temperatures are reached
(TM 5-5420-202-10).
2.
Check tachometer for indication of 700-750 rpm. If indication is not within
range, adjust idle adjusting screw according to steps 3 through 6.
3.
Using 1/2 inch wrench, loosen jamnut on idle adjusting screw.
4.
Using 1/2 inch wrench, adjust idle adjusting screw until 700-750 rpm shows on
tachometer.
5.
Using 1/2 inch wrench, tighten jamnut.
6.
Install 3/16 inch end of throttle linkage adjusting gage between stop pin and bracket
shoulder. If distance is not a minimum of 3/16 inch, notify support maintenance.
7.
Check tachometer. If indication is not between 700-750 rpm, notify maintenance
supervisor.
Go on to Sheet 7