CENTRIFUGAL FAN HOUSING REPLACEMENT
CENTRIFUGAL FAN HOUSING REPLACEMENT - Continued

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -2 Page Navigation
  688    689    690    691    692  693  694  
img
.
TM 5-5420-202-20-2
CENTRIFUGAL FAN HOUSING Replacement (Sheet 2 of 3)
Remove fan housings (B) from powerplant.
2.
Using 1/2 inch socket, remove ten screws
3.
(C) securing covers (D) to shroud (E).
Remove covers (D) from powerplant.
4.
Using two 9/16 inch wrenches, remove
5.
two screws, lockwashers and nuts (F)
that hold housing (G) and mount (H)
together.
6.
Using 9/16 inch socket, remove four
screws (J).
7.
Remove housing (G) and mount (H) from
powerplant.
INSTALLATION:
NOTE
Make sure no foreign matter is present in
fan housing.
Position mount (A) and housing (B) onto
1.
powerplant.
Using two 9/16 inch wrenches, install
2.
two screws, lockwashers, and nuts (C)
securing mount (A) and housing (B) together
3.
Using 9/16 inch socket, install four
screws (D) securing mount (A) and housing
(B) to engine shroud.
4.
Using feeler gage, check clearance
between tip of each fan blade and
housing (B). If clearance is less
than 0.062 inch, loosen screws (D)
and shift housing (B) until
clearance is obtained.
Go on to Sheet 3