• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
INFRARED STOWAGE RECEPTACLE ASSEMBLY REPLACEMENT (Sheet 1 of 1)
MASTER RELAY MOUNTING PLATE AND BRACKET REPLACEMENT (Sheet 2 of 2)

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -3 Page Navigation
  160    161    162    163    164  165  166    167    168    169    170  
img
. .
TM 5-5420-202-20-3
MASTER RELAY MOUNTING PLATE AND BRACKET REPLACEMENT (Sheet 1 of 2)
TOOLS:
9/16 in. socket with 1/2in. drive
1/4 in. drive punch
1/2 in. socket with 1/2 in. drive
Hammer
Ratchet with 1/2 in. drive
SUPPLIES
Nut (2 required)
Lockwashers (4 required)
Remove master relay assembly (page 10-138)
PRELIMINARY PR0CEDURE:
REMOVAL:
1.
Using 1/2 inch socket, remove
two screws (A), and lockwashers
(B) securing bracket (C) to
plate (D).
2.
Remove mounting bracket (C).
3. Using 9/16 inch socket, remove
two screws (E), and lockwashers
(F).
4. Using 9/16 inch socket, remove
two screws (G) and lockwashers (H).
5. Remove plate (D) from vehicle to work
bench.
6. Using hammer and punch, tap out
two nuts (J). Throw away nuts (J).
TA249102
Go on to Sheet 2