TM 5-5420-202-20-3
AIR CLEANER MOTOR SOLENOID RELAY REPLACEMENT (Sheet 1 of 2)
TOOLS:
Spanner wrench
3/8 in. socket with 1/2 in. drive
Ratchet with 1/2 in. drive
Lockwashers (2 required)
SUPPLES:
PRELIMINARY PROCEDURE:
Remove access plate from floor at commander's station.
(page 17-9)
REMOVAL:
1.
Using spanner wrench, remove electrical connector (A) from air cleaner motor solenoid
relay (B).
Using socket, remove two screws
and lockwashers (D) securing air
cleaner motor solenoid relay (B).
Remove air cleaner motor relay
3.
(B) from mounting plate (E).
TA249104
Go on to Sheet 2
10-163