TM 5-5420-202-20-3
FUEL TANK CAPACITOR AND HOUSING
ASSEMBLY REPLACEMENT (RIGHT)
(Sheet 3 of 5)
14.
Using screwdriver, remove four screws
(W) and washers (X) from cover (U) and
adapter (T).
15.
Separate cover (U), gasket (Y), and
adapter (T). Discard gasket (Y).
CLEANING AND INSPECTION:
1.
Using putty knife, clean all areas where gaskets were mounted.
WARNING
To prevent personal injury, wear
Dry cleaning solvent P-D-680 is toxic and flammable.
protective goggles and gloves and use only in a well-ventilated area. Avoid contact with skin,
eyes, and clothes and don't breathe vapors. Do not use near open flame or excessive heat. The
flash point for Type #1 Dry Cleaning Solvent is 100F (38C) and for Type #2 is 138F (50C).
If you become dizzy while using cleaning solvent, get fresh air immediately and get medical aid.
If contact with eyes is made, wash your eyes with water and get medical aid immediately.
2.
Using dry cleaning solvent and lint-free cloth, wipe gasket surfaces clean.
3.
Inspect cable, adapter and cover for
damage. Replaced damaged parts.
INSTALLATION:
1. Position new gasket (A), and cover (B)
onto adapter (C).
2. Using screwdriver, install four screws (D)
and washers (E) securing cover and
gasket (A) to adapter (C).
Go on to Sheet 4
TA249260