7.
Using hand wire stripper, strip insulation
from jumper wire equal to depth of contact
solder well (F).
Placing connector face down on flat
8.
surface, apply a small amount of silicone
to empty holes on back of plug assembly
(B) and on front of grommet (D).
Push new contact (E) into hole in back of
9.
plug assembly (B) far enough so it will
remain standing.
Push jumper wire end, first through
10.
grommet retaining nut (A) and then
through hole in grommet (D).
Hold jumper wire so wire end is pushing
11.
down into solder in contact solder well (F).
12.
contact (E) until solder begins to welt
and wire slips into contact solder well (F).
13.
(E), continue holding wire until solder has
cooled and set.