SMOKE GRENADE DISCHARGER WIRING HARNESS ASSEMBLY REPLACEMENT - Continued
SMOKE GRENADE DISCHARGER BRACKET DUMMY RECEPTACLE REPLACEMENT - Continued

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -4 Page Navigation
  278    279    280    281    282  283  284    285    286    287    288  
img
.
TM 5-5420-202-20-4
SMOKE GRENADE DISCHARGER BRACKET DUMMY RECEPTACLE REPLACEMENT
(Sheet 1 of 2)
TOOLS: Slip joint pliers, conduit style, with plastic jaw inserts
Flat-tip screwdriver
Lockwashers (4 required)
SUPPLIES:
Gasket
REMOVAL:
Make sure there are no smoke
grenades in dischargers. Acci-
dental firing of grenade could
hurt or kill you.
NOTE
R e m o v a l procedures are the
same for both the left and right
dummy receptacles.
Using pliers, disconnect electrical
1.
connector (A) of discharger harness (B)
from back of discharger (C).
Using screwdriver, remove four screws (D)
2.
and lockwashers (E) securing dummy
receptacle (F) and gasket (G) to discharger
bracket (H).
Take dummy receptacle (F) and gasket (G)
3.
off discharger bracket (H). Discard
gasket.
Go on to Sheet 2
TA249168