TM 5-5420-202-20-4
MATERIAL
DESCRIPTION
FABRICATING REQUIREMENT
STOCK SIZE
1. If using 20 ft. wire, cut
Connector, electrical
MS3106R10SL4SC
in 10 ft. lengths and
connect to connector.
Wire, black, electrical
M1348611-3
16 ga., 20 ft. lg
2. If using optional wire,
Wire, black, electrical
(OPT) M227591/1616-0
connect one black wire
16 ga., 10 ft. lg
and one red wire to
connector.
Wire, red, electrical
(OPT) M22759/16-16-2
16 ga., 10 ft. lg
3. Wrap electrician's tape
around both wires at
(OPT) M81044/12-16-0 Wire, black, electrical
connector.
16 ga., 10 ft. lg
4. Cut two 3 inch long
Wire, red, electrical
(OPT) M81044/12-16-2
pieces of heat shrink
16 ga., 10 ft. lg
tubing and slide one
piece onto each wire.
Power clip (2 required)
W-C-440B Type PC4
8/32 UNC-2A X 1/4 lg Screw (2 required)
to each wire.
Heat shrink tubing, 1 ft. lg
MILR-46846, Type V
6. Connect lug terminals
to power clips with
Lug Terminal
7056709
screws and bend ears
of power clips over
wires.
Electricians tape (Item 59,
NSN 5970-00-419-3164
7. Slide heat shrink
tubing onto power
clip connection and
using heat gun, shrink
tubing.
TA248939
Figure F-7. Fuel- Water Separator Test Cable
F-7