TM 5-5420-209-12Table 4-2. Unit Preventive Maintenance Checks and Services (PMCS) for the Ramp Bay cont.LocationItemNo.IntervalItem toItem To Be InspectedEquipment Is NotProcedureService/CheckReady/Available If30WeeklyLifting Eye(Rear)Inspect for cracks and elongation of eye.Any cracks noted or eyeelongation equals 25%of originalcircumference.31WeeklyDeck SurfaceInspect for punctures, cracks, tears, dents,Any damage whichholes and broken welds.allows water into baycavity.Check condition of non-skid coating.32WeeklyBilge PlugEnsure plug(s) are secured with wire rope toAny plug missing.ponton.Ensure plug(s) aresecured with wire ropeto ponton.Inspect rubber seal for cuts, elasticity and dryrot.Check handle operation.NOTEReceptacle consists of entirehousing (Block) in whichconnector is seated.33WeeklyConnectorReceptacleInspect seams for broken welds.Inspect receptacle area for cracks, brokenwelds, elongation and deformation.Cracks or broken weldsnoted. Elongation ordeformation preventsproper seating ofconnector.NOTEProper connector has anarrow canter bar (0.500inch); older connectors havethicker (.69) in center bar.Loose or missing set screwswill allow water into bay cavity.34WeekIyRoadwayEnsure connector is correct type.ConnectorsInspect connector, eye bracket, set screws,spring and spring pins for cracks anddeformation.of connector.35WeeklyHydraulic PumpInspect covers for cracks and deformation.Access coverand Data PlatesInspect plates for legibility.Incorrect connector type.Any defect whichprevents proper seatingAny cover missing.4-16 Change 1P I N : 0 2 7 5 0 2 - 0 0 1