ARMY TM 5-5420-212-10-1
MARINE CORPS TM 08676A-10/1-1
The first stage uses three deck units placed in their final position.
The second stage uses twenty seven deck units and six curbs. Five deck units are placed in their final position on
the end of bridge next to the three placed at the first stage. Two curbs are placed on the bankseat beam and four curbs
on the top panels to retain the counterweight. The additional twenty two deck units are placed on decking, sixteen laid flat
and six on their edge leaning toward deck units as shown.
7-7.
2E + 22 BAY - NORMAL SITE
On 2E + 22 bay link reinforced bridges, forty deck units and six curbs are placed on the rear end of bridge as
counterweight. The counterweight is added in two stages.
The first stage uses three deck units (para. 7-6).
The second stage uses thirty seven deck units and six curbs. Five deck units are placed in their final position on
the end of bridge next to the three placed at the first stage. Two curbs are placed on the bankseat beam and four curbs
on the top panels to retain the counterweights. The additional thirty two deck units are placed on decking, twenty four laid
flat and eight on their edge leaning toward deck units as shown.
7-39