TM 5-5420-226-20-2
AIR CLEANER OUTLET HOSE ASSEMBLY R E P L A C E M E N T ( S h e e t 2 o f 3 )
Pull pin (A) and release quick release
2.
clamp (B).
Remove quick release clamp (B) from
3.
hose and elbow.
Using socket, loosen nut (C) securing
4.
clamp (D).
Remove hose assembly (E).
5.
Remove clamp (D).
6.
Cover air cleaner outlet elbow and turbosuperchager inlet elbow with rags to prevent
7.
entrance of foreign matter.
Inspect hose assembly (E) for damage or defective parts. Replace hose assembly if hose or
8.
flange is unserviceable.
If hose (F) is serviceable, remove preformed
9.
packings (G) from ends of hose assembly
flanges. Throw packings away. Using knife,
clean old adhesive from grooves in flanges.
INSTALLATION:
NOTE
If installing new hose assembly, skip step 1 and 2.
1.
Apply adhesive to
grooves in flanges in hose (A).
2.
Install new preformed packings (B) into
grooves in flanges.
Go on to Sheet 3
Change 2