AIR CLEANER BLOWER FAN REPLACEMENT - Continued
AIR CLEANER BLOWER FAN REPLACEMENT - Continued

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -2 Page Navigation
  284    285    286    287    288  289  290    291    292    293    294  
img
.
TM 5-5420-226-20-2
AIR CLEANER BLOWER FAN REPLACEMENT (Sheet 3 of 7)
7.
Disconnect blower fan lead (H) from
ground lead (J).
8.
Using socket and extension, remove
two screws and washers (K) securing
strap (L).
Remove strap (L).
9.
10.
Remove blower fan (G).
11.
Disconnect jumper lead (M) from blower
fan lead.
12.
Using socket and extension, remove
screw (N) and washer (P).
13.
Remove support (Q) and pad (R).
INSPECTION AND REPAIR:
1.
Inspect gasket on housing. If damaged or
deteriorating, replace.
TA107711
Go on to Sheet 4