• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
AIR CLEANER BLOWER FAN REPLACEMENT - Continued
AIR CLEANER BLOWER FAN GROUND LEAD REPLACEMENT

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -2 Page Navigation
  289    290    291    292    293  294  295    296    297    298    299  
img
. . .
TM 5-5420-226-20-2
AIR CLEANER CIRCUIT BREAKER REPLACEMENT (Sheet 1 of 1)
Cross-tip screwdriver
TOOLS:
1/2in. socket with 1/2 in. drive
Ratchet with 1/2 in. drive
REFERENCE: TM 5-5420-226-10
NOTE
All air cleaner circuit breakers are
removed and installed the same way.
REMOVAL:
Using socket, remove 10 screws (A) and lockwashers (B) securing cover (C).
1.
2.
Using screwdriver, remove screws (D) and washers (E) securing circuit breaker (F) to
cover (C).
Remove circuit breaker (F).
3.
Disconnect two electrical leads
4.
(circuit 415).
INSTALLATION:
Position circuit breaker (F) onto
1.
cover (C).
Install washers (E) and screws (D) to secure
2.
circuit breaker (F) to cover (C). Use cross-
tip screwdriver and tighten screws (D).
Connect two electrical leads (circuit 415).
3.
Install cover (C) and secure with 10 screws (A)
4.
and lockwashers (B).
Using socket, tighten screws (A).
5.
Check operation of blowers
6.
(TM  5-5420-226-10).
TA107716
End of Task
7-111


Privacy Statement