TM 5-5420-226-20-2
AIR CLEANER CIRCUIT BREAKER REPLACEMENT (Sheet 1 of 1)
Cross-tip screwdriver
TOOLS:
1/2in. socket with 1/2 in. drive
NOTE
All air cleaner circuit breakers are
removed and installed the same way.
REMOVAL:
Using socket, remove 10 screws (A) and lockwashers (B) securing cover (C).
1.
2.
Using screwdriver, remove screws (D) and washers (E) securing circuit breaker (F) to
cover (C).
Remove circuit breaker (F).
3.
Disconnect two electrical leads
4.
(circuit 415).
INSTALLATION:
Position circuit breaker (F) onto
1.
cover (C).
Install washers (E) and screws (D) to secure
2.
circuit breaker (F) to cover (C). Use cross-
tip screwdriver and tighten screws (D).
Connect two electrical leads (circuit 415).
3.
Install cover (C) and secure with 10 screws (A)
4.
Using socket, tighten screws (A).
5.
Check operation of blowers
6.
TA107716
End of Task