• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
AIR CLEANER BLOWER COVER AND GASKET REPLACEMENT - Continued
AIR CLEANER BLOWER FAN REPLACEMENT

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -2 Page Navigation
  281    282    283    284    285  286  287    288    289    290    291  
img
.
TM 5-5420-226-20-2
AIR CLEANER BLOWER FAN HOSE REPLACEMENT (Sheet 1 of 1)
Flat-tip screwdriver
TOOLS:
1/2in. socket with 1/2in. drive
Ratchet with 1/2 in. drive
Silicone compound (Item 32, Appendix D)
SUPPLIES:
NOTE
Removal of left or right blower
fan hose is the same. Left side shown.
REMOVAL:
1.
Using socket, remove 10 screws (A) and
lockwashers (B) securing cover (C).
Using flat-tip screwdriver, loosen clamps (D).
2.
Slide clamps (D) onto hose (E).
3.
Remove hose (E) from blower fan (F) and
4.
housing (G).
Inspect hose (E) and clamps (D). Replace
5.
as necessary.
INSTALLATION:
Position clamps (D) onto hose (E).
1.
Coat inside diameter of hose ends with
2.
silicone compound and install hose (E)
to blower fan (F) and housing (G).
Slide clamps (D) to ends of hose. Use flat-tip screwdriver and tighten clamps (D).
3.
Install cover (C) and secure with 10 screws (A) and lockwashers (B).
4.
Using socket, tighten screws (A).
5.
TA107708
End of Task
7-103