TM 5-5420-226-20-2
FUEL SHUTOFF CABLE ASSEMBLY REPLACEMENT (Sheet 4 of 15)
NOTE
Clamp (P) is located through subfloor
access plate directly in front of operator's
seat. Clamp (Q) is attached at the battery
box.
8. Using 7/16 inch socket, remove both
clamps (p) and (Q). Remove clamps (P)
and (Q).
Using screwdriver, loosen clamp (T)
9.
and slide it forward on cable assembly
(H).
10.
Using hands, pull cable
assembly (H) forward to
dislodge grommet (U) from
bulkhead connector (V).
11. Remove grommet (U) from
cable assembly (H).
12. Using putty knife, remove
bushing (W) from cable
assembly (H). Throw bushing
(W) away.
TA107775
G O on to Sheet 5
7-168