TM 5-5420-226-20-2
FUEL TANK CONDENSATE REMOVAL (Sheet 2 of 6)
NOTE
Steps 2 and 3 apply to removal of dust covers from
hand fuel pump and hoses.
2.
Using fingers in clamp ring (D), pull
clamps (E) out and down against body
of connector (F) to loosen dust cover
(G).
3.
Remove dust cover (G) from connector
(F).
4.
Install hose (H) on connector (F) on
discharge side of hand fuel pump
(A).
5. Using fingers in clamp ring (D), pull
clamp (E) out and up against hose (H)
to clamp hose (H) in place.
6. Repeat steps 4 and 5 for installing
hose on connector on suction side of
hand fuel pump (A).
Go on to Sheet 3
TA107793
7-186