TM 5-5420-226-20-2
FUEL TANK CONDENSATE REMOVAL (Sheet 4 of 6)
REMOVING CONDENSATE:
CAUTION
Use care not to spill fuel over tank. Wipe away any spilled fuel imme-
diately with rags.
1.
Operate pump handle (A) to transfer
fuel from fuel tank to 55 gallon drum (B).
2.
Continue operating pump handle (A)
until all fuel has been removed from
fuel tank.
REMOVAL OF HAND PUMP:
1.
Using one hand to push quick-disconnect
(A) down, remove adapter (B) from
quick-disconnect (A).
Install dust cover (C) on quick-disconnect
2.
(A) by pushing dust cover (C) down
until it snaps into place.
Remove adapter (B) from suction hose (D).
3.
Go on to Sheet 5
TA107795