TM 55-5420-202-342
TM -5420-226-20-
FUEL SHUTOFF CABLE ASSEMBLY REPLACEMENT (Sheet 1 of 13)
PPOCEDURE INDEX
PAGE
PROCEDURE
Removal
Installation
TOOLS:
5/8 in. open end wrench
7/16 in. socket with 1/2 in. drive
7 / 1 6 i n . open end w r e n c h ( 2 required)
Screwdriver flat tip
1/2 in. open end wrench (2 required)
9/16 in. open end wrench
3/4 in. open end wrench
15/16 in. open end wrench (2 required)
Slip joint pliers
Putty knife
Bushing
SUPPLIES:
Packing
Wire (8 to 10 ft) (Item 62, Appendix D)
Adhesive (Item 4, Appendix D)
Grommet
PERSONNEL: Two
PRELIMINARY PROCEDURES:
Remove subfloor access cover, directly in front of operator's
seet (page 17-8).
R am o v e
subfloor access cover, directly in front of
operator's seat (TM 5-5420-202-20)
Go on to Sheet 2
7-442
4- 04
Change 6