TM 5-5420-226-20-3
MASTER CONTROL PANEL REPAIR (Sheet 41 of 73)
Minter Heater Switch, Hi-Lo Switch And Indicator Light Replacement (Sheet 2 of 8)
REMOVAL:
1. Using flat-tip screwdriver on screws (A)
and 11/32 inch wrench on nuts (B), remove
nuts (B) securing connector (D) to panel.
2. Remove connector (D) from panel and
position aside.
3. Using flat-tip screwdriver on screw (E)
and 11/32 inch wrench on nut (F), remove
nuts (F) securing connector (H) to panel.
4. Remove connector (H) from panel and
position aside.
Go on to Sheet 3
TA168729